Navien Furnace: Alternate drain piping using PVC or CPVC
Alternate drain piping using PVC or CPVC on a Navien furnace: The factory rubber hoses at the trap can be used with rigid PVC or CPVC drain piping. Match the hose to the pipe size and seal with a coupling or bushing.
Applies to: NDF condensate drain system
How to fix alternate drain piping using pvc or cpvc: step by step
- Install the condensate trap per this manual.
- For 1/2 in. PVC, use the 1/2 in. hose. For 3/4 in. CPVC, use the 5/8 in. hose.
- Slide the hose over the trap outlet and cut it flush with the outlet end.
- Fit a 1/2 in. PVC coupling or bushing over the 1/2 in. hose, or a 3/4 in. CPVC coupling or bushing over the 5/8 in. hose, for a watertight seal that still allows trap removal.
- Optionally secure a strip of strapping around the drain using the existing trap screws.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF Installation and Operation Manual, p. 46. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.