Navien Furnace: Adjust gas/air ratio using a combustion analyzer
Adjust gas/air ratio using a combustion analyzer on a Navien furnace: Set the CO2 with a combustion analyzer, which the manual recommends. Confirm high altitude and gas type first.
Applies to: NPF700 furnaces, gas conversion or altitude change
How to fix adjust gas/air ratio using a combustion analyzer: step by step
- Turn on the gas and water supply (if a supply water valve is used).
- Remove the analyzer port cap and insert the analyzer probe into the port.
- Put the furnace in heating mode and set it to MIN (low fire).
- Read the CO2 and compare it with Table 2 for the model, altitude and gas type.
- If CO2 is off by more than 1.0%, turn the gas valve set screw using a 5/32 in or 4 mm Allen wrench. The screw is under a screw-on cover, so remove that first.
- Turn the screw no more than 1/4 turn: clockwise raises CO2, counterclockwise lowers it.
- Put the furnace in heating mode and set it to MAX (high fire).
- Read CO2 at high fire. If it does not match Table 2, do not adjust the gas valve; check for the correct gas orifice instead.
- Once CO2 or offset values are confirmed, apply the conversion labels next to the rating plate.
- Reinstall the upper front cover, seat it fully against the furnace, and tighten the three knobs clockwise.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 136-137. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.