Navien Furnace: Adjust gas valve offset using a digital manometer
Adjust gas valve offset using a digital manometer on a Navien furnace: Alternative to the analyzer method. Measure the offset pressure at the offset port at low fire.
Applies to: NPF700 U and H models, gas conversion or altitude change
How to fix adjust gas valve offset using a digital manometer: step by step
- Loosen the offset pressure port screw two turns to open the port.
- Connect a digital manometer to the offset port. On dual port manometers, use the positive side.
- Put the furnace in heating mode and set it to MIN (low fire).
- Read the offset and compare it with Table 3 for the model, altitude and gas type.
- If the offset is out of range, remove the screw-on cover and turn the set screw no more than 1/4 turn: clockwise raises the offset, counterclockwise lowers it.
- At high fire, do not check the offset and never adjust the gas valve.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 137-138. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.