Updated · by Aurora Star Tech Inc.

CH series E040 outdoor sensor shorted - full check on a Navien combi boiler: E040 shows when the outdoor sensor reads 122°F (50°C) or more with the boiler on.

Homeowner with a combi boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers

Common causes of ch series e040 outdoor sensor shorted - full check

  • Outdoor sensor wire shorted or connector bad
  • Failed outdoor sensor
  • Bad PCB

How to fix ch series e040 outdoor sensor shorted - full check: step by step

  1. Turn off power before unplugging connectors or measuring resistance.
  2. Check the outdoor sensor wiring and plug.
  3. Test the sensor and replace if bad.
  4. If the sensor is good, replace the PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Combi Boiler codes

Models

CH-180 ASMECH-210 ASMECH-240 ASME

Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.27 40 Error p.107. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.