Navien Combi Boiler: CH series E039 water flow sensor (cascade) – full check
CH series E039 water flow sensor (cascade) - full check on a Navien combi boiler: E039 is a flow sensor fault seen when more than one unit runs in a cascade. The boiler locks out (manual reset).
Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers
Common causes of ch series e039 water flow sensor (cascade) - full check
- No cold water to the unit (frozen or closed valve)
- Flow sensor connector or sensor failed
- Bad PCB
How to fix ch series e039 water flow sensor (cascade) - full check: step by step
- Turn off power before unplugging connectors or measuring resistance.
- Take the unit out of the cascade and open a hot tap.
- No water flow: check the cold water supply and valves.
- Water flows but still faults: check the flow sensor plug, then replace the sensor.
- If all checks pass, replace the PCB.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.26 39 Error p.106. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.