Navien Combi Boiler: CH series E015 PCB error – full check
CH series E015 PCB error - full check on a Navien combi boiler: E015 means the board found a fault in its own circuit.
Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers
Common causes of ch series e015 pcb error - full check
- Failed PCB
- Supply voltage out of range
- Electrical noise on the ground
How to fix ch series e015 pcb error - full check: step by step
- Turn off power before unplugging connectors or measuring resistance.
- Measure the outlet: 97-138 VAC.
- Press reset. If it comes back normal, watch it.
- Test for ground noise: tape over the ground pin at the receptacle as a short test only, and see if the board behaves. Restore the ground right after.
- If voltage is fine and the fault stays, replace the PCB.
If the unit shows an error code, look it up: Navien Combi Boiler codes
Models
CH-180 ASMECH-210 ASMECH-240 ASME
Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.15 15 Error p.86. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.