Weil-McLain Boiler: Zoning with circulators: four space heating zones
Zoning with circulators: four space heating zones on a Weil-McLain boiler: Four space heating zones with no Indirect DHW, using thermostat inputs and circulator outputs. Shown for Heating Only models.
Applies to: ECO Tec Series 3 Heating Only models
How to fix zoning with circulators: four space heating zones: step by step
- Wire zone thermostats to J17-1/2, J17-4/5, J17-7/8 and J16-1/2.
- Wire circulators to Outputs 1 to 4 (2.2 A max each).
- During the WIZARD, choose the space heating system type that matches the heating system, or set it manually in the PRIORITY 2 menu of System Settings.
- Use the factory default settings for that system type, or change them if needed.
- Review the 120VAC output wiring on page 68 and the 24VAC input wiring on page 69.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec Series 3 boiler manual, p. 75. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.