Updated · by Aurora Star Tech Inc.

Wire 120VAC power supply and grounding on a Weil-McLain boiler: Line voltage power is required. The boiler must be grounded and bonded.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3 all models

How to fix wire 120vac power supply and grounding: step by step

  1. Turn off power at the service entrance panel before making any electrical connections.
  2. Provide a properly sized fused disconnect or service switch (15 A for most cases; boiler total draw is under 12 A).
  3. Connect 120VAC power to line voltage terminal block T1 (hot, neutral, and ground).
  4. Wire the ground to the boiler ground terminal. Improper grounding can cause abnormal operation and hazards.
  5. If possible, add a surge suppressor on the supply power line.
  6. Use type 105 °C wire if original supplied wiring must be replaced.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 condensing gas boiler boiler manual, p. 65-68. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977