Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Boiler: Tankless water heater only piping

Updated · by Aurora Star Tech Inc.

Tankless water heater only piping on a Weil-McLain boiler: Boiler can supply an on-demand tankless water heater only, piped as shown in Figure 61.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Tankless DHW installations

How to fix tankless water heater only piping: step by step

  1. Fill and pressurize the boiler and complete the hydrostatic test first.
  2. Pipe the hydronic side as a closed loop with primary/secondary piping.
  3. Pipe domestic water only to the secondary heat exchanger through the domestic manifolds, never to the primary heat exchanger.
  4. Pipe the expansion tank into the system as shown; move it to the correct location when space heating is added.
  5. Add a low water cut-off and other limit controls as required on page 47.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec Series 3 boiler manual, p. 52. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977