Weil-McLain Boiler: Servicing the domestic water inlet manifold (flow transducer and bypass filter)

Updated · by Aurora Star Tech Inc.

Servicing the domestic water inlet manifold (flow transducer and bypass filter) on a Weil-McLain boiler: Clean the inlet filter, check the O-ring and bypass filter, then reassemble.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 80/110/150/199 Series 3

How to fix servicing the domestic water inlet manifold (flow transducer and bypass filter): step by step

  1. Follow the gas and electrical shut-off steps and the brazed plate steps 1-4 on the previous page.
  2. Lift the flow sensor electronic pickup off the flow transducer/turbine, keeping its wire attached.
  3. Remove the flow transducer/turbine with an 18mm hex socket.
  4. Detach the filter and clean it by pushing air or water through it, opposite to normal flow. Do not damage the plastic filter.
  5. Check the O-ring and seat in the inlet manifold. Replace the O-ring if damaged.
  6. Reassemble the transducer and filter, reinsert into the block and torque to the value in the torque table.
  7. Push the flow sensor pickup back on and confirm its wires are still connected.
  8. Remove the bypass filter with a 16mm (5/8 in) wrench. Clean with water if needed. Confirm the spring is relaxed and in good condition.
  9. Reinsert the bypass and torque to the value in the torque table.
  10. The boiler inlet water temperature sensor sits in this manifold. Verify it using the temperature sensor check.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 boiler manual, p. 157. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.