Updated · by Aurora Star Tech Inc.

Removing the boiler from the shipping pallet on a Weil-McLain boiler: Handle the boiler carefully and remove it from the pallet in the proper order.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Ultra Series 4 boilers

How to fix removing the boiler from the shipping pallet: step by step

  1. If stored below 0 F, let plastic parts reach room temperature before handling.
  2. Remove the outer carton, then remove the jacket front door by loosening two lower front screws.
  3. Remove the lag screws holding the shipping brackets.
  4. Unscrew the two rear boiler legs and remove the shipping brackets.
  5. Reinstall the boiler legs.
  6. Discard the cardboard protector insert on the rear of the boiler.
  7. Do not drop the boiler or bump the jacket on the floor or pallet.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Weil-McLain Series 4 gas-fired water boiler manual, p. 7. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.