Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Boiler: Removing the boiler from a shared common vent

Updated · by Aurora Star Tech Inc.

Removing the boiler from a shared common vent on a Weil-McLain boiler: When this boiler leaves a common vent that other appliances still use, each remaining appliance must be checked by itself to confirm it still vents properly. Any venting fault found must be corrected to the National Fuel Gas Code.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Boiler replacement on a shared common vent

Common causes of removing the boiler from a shared common vent

  • Undersized or pitched-wrong vent shared by other appliances
  • Blockage, restriction, leakage or corrosion in the common vent
  • Spillage from a remaining appliance when run alone with exhaust fans on

How to fix removing the boiler from a shared common vent: step by step

  1. Seal any unused openings in the common vent.
  2. Inspect the vent for proper size, horizontal pitch, blockage, restriction, leakage and corrosion.
  3. Close exterior doors and windows and doors to other spaces; turn on clothes dryers and non-vented gas appliances; run bathroom and range hood exhaust fans at maximum speed; close fireplace dampers. Do not run a summer exhaust fan.
  4. Run the remaining appliance alone with its thermostat set so it runs continuously.
  5. After 5 minutes of main burner operation, check for spillage at the draft diverter relief opening with a match or candle flame.
  6. If spillage occurs, correct the vent system before the install is complete.
  7. Return doors, windows, fans, fireplace dampers and other gas appliances to their original state.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: EG / PEG Series 7 Boiler Manual, pp. 10-11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.