Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Boiler: Remove the cover plate and inspect the burner

Updated · by Aurora Star Tech Inc.

Remove the cover plate and inspect the burner on a Weil-McLain boiler: The cover plate nut count depends on model: four nuts on the 110, five on the 150 and six on the 199. Handle the cover plate and burner assembly carefully so the bottom insulation and seal are not damaged.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3 boilers

How to fix remove the cover plate and inspect the burner: step by step

  1. Remove the cover plate nuts with a 10mm wrench or socket: four on the 110, five on the 150, six on the 199.
  2. Lift the cover plate assembly straight up until the insulation clears the heat exchanger studs, then pull it forward out of the cabinet.
  3. Place the assembly upside down on a clean, flat surface and watch the blower studs.
  4. Slide the bottom cover plate insulation with integrated seal off the burner and set it aside clean. Replace it if the insulation or seal is damaged.
  5. Remove the burner and its gasket with the T20 Torx driver. Discard the old gasket.
  6. Inspect the burner insulation on the cover plate and replace it if damaged or worn.
  7. Clean the burner flange and cover plate surface to remove all old gasket material.
  8. Inspect the inside of the burner. Brush and vacuum it, or blow air from inside out, rinse with water spray, or swirl in mild laundry detergent water and rinse well.
  9. Inspect the burner exterior. Replace it if visibly damaged.
  10. Get a new burner gasket before reinstalling.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 boiler manual, p. 150-151. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977