Weil-McLain Boiler: Never common vent the ECO Tec with another appliance
Never common vent the ECO Tec with another appliance on a Weil-McLain boiler: The ECO Tec cannot share a common vent with any other appliance. When an old boiler is replaced, the ECO Tec must have its own vent and air piping. The remaining appliances on the old common vent may then be oversized and need to be checked.
Applies to: ECO Tec Series 3 replacing a boiler on a common vent
How to fix never common vent the eco tec with another appliance: step by step
- Do not connect the ECO Tec to an existing common vent.
- Install new vent and air piping as specified in this manual.
- Check the remaining appliances on the old vent for proper venting (see the vent verification guide).
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec series 3 boiler manual, p. 25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.