Weil-McLain Boiler: Mount and wire controls – EG-30 to EG-75 water boilers
Mount and wire controls - EG-30 to EG-75 water boilers on a Weil-McLain boiler: Control box mounting and wiring for EG-30 through EG-75 water boilers, with or without tankless heater. Figure 40 (no tankless heater) and Figure 41 (with tankless heater) are the reference drawings. Wiring diagram is on page 36.
Applies to: EG-30 to EG-75 water boilers, with and without tankless heater
How to fix mount and wire controls - eg-30 to eg-75 water boilers: step by step
- Turn off electrical power and the external gas supply valve before working on the boiler.
- Attach the junction box inside the left jacket panel with the #8-32 x 1/2 inch machine screws provided.
- Mount the 24VAC transformer to the interior jacket panel with #10 x 1/2 inch screws and lock washers, using the holes below the boiler control.
- Secure the chassis ground splice ring terminal to the interior jacket panel with the #8 x 3/8 inch screw, using the hole to the right of the transformer.
- Run the 120VAC supply wiring to the boiler using 14 gauge or heavier wire.
- Run operating and limit circuit wiring using 18 gauge or heavier wire.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: EG / PEG Series 7 Boiler Manual, p. 49-50. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.