Updated · by Aurora Star Tech Inc.

Massachusetts sidewall horizontal vent: required safety items on a Weil-McLain boiler: Applies to sidewall horizontally vented gas equipment in residential buildings where the vent terminal is less than 7 feet above finished grade, including over decks and porches. Boiler must be installed by a licensed plumber or gas fitter. Listed equipment in NFPA 54 Chapter 10 and product-approved equipment in a separate structure are exempt.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Ultra boilers with sidewall vent in Massachusetts

How to fix massachusetts sidewall horizontal vent: required safety items: step by step

  1. Confirm a hard-wired CO detector with alarm and battery backup is installed on the floor where the boiler is located.
  2. Confirm a battery-operated or hard-wired CO detector with alarm is installed on each additional level served.
  3. If the boiler is in a crawl space or attic, the hard-wired detector may go on the next adjacent floor.
  4. If detectors cannot be completed at install, the owner has 30 days to complete them, and a battery-operated CO alarm must be installed in the meantime.
  5. Use CO detectors that meet NFPA 720, are ANSI/UL 2034 listed and IAS certified.
  6. Mount a metal or plastic sign on the outside wall at least 8 feet above grade, directly in line with the vent terminal. Lettering must be at least 1/2 inch and must warn that the gas vent is directly below and must be kept clear.
  7. Use only plastic vent pipe that the boiler manufacturer allows, that is listed to a venting standard, and that is accepted by the state board.
  8. Leave all installation, venting and parts instructions with the appliance.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Ultra Series 4 boiler manual, p. 65. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.