Weil-McLain Boiler: Low flame signal troubleshooting

Updated · by Aurora Star Tech Inc.

Low flame signal troubleshooting on a Weil-McLain boiler: Use when the running flame signal stays low.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3 gas boilers

Common causes of low flame signal troubleshooting

  • Fouled ignition electrode
  • Damaged electrode insulation
  • Poor ground wiring
  • Fouled heat exchanger
  • Venting or combustion problem

How to fix low flame signal troubleshooting: step by step

  1. Remove and inspect the ignition electrode (p. 141).
  2. Clean the electrode if needed.
  3. If cleaning does not help and ground wiring and continuity are good, replace the ignition electrode.
  4. If the signal is still low, inspect the vent and air piping.
  5. Check combustion values.
  6. Inspect and clean the heat exchanger per the cover plate procedure (p. 151).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 boiler manual, p. 142. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.