Weil-McLain Boiler: Installing EG water boiler flue baffles
Installing EG water boiler flue baffles on a Weil-McLain boiler: The installer must fit all flue baffles for correct boiler operation. Each baffle is slid between the sections.
Applies to: EG water boilers
How to fix installing eg water boiler flue baffles: step by step
- Bend the two tabs on each flue baffle about 90 degrees in opposite directions so it will not fall through the flue way.
- Slide each baffle between sections with the notch down and toward the back.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: EG / PEG Series 7 Boiler Manual, p. 15 (see Figure 5). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.