Weil-McLain Boiler: Install the draft hood on the flue collector hood
Install the draft hood on the flue collector hood on a Weil-McLain boiler: A gas-tight joint at the draft hood prevents flue gas spillage.
Applies to: All Series 7 boilers with draft hood
How to fix install the draft hood on the flue collector hood: step by step
- Attach the draft hood to the flue collector hood with #10 x 1/2 in. sheet metal screws supplied.
- Seal the joint with the boiler cement supplied.
- Do not alter the draft hood or add any obstruction or non-approved damper in the breeching or vent. This voids CSA certification.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: EG/PEG Series 7 boiler manual, p. 18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.