Updated · by Aurora Star Tech Inc.

Install the condensate trap on a Weil-McLain boiler: Assemble the trap so the float is in place and the connections are sealed.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: SVF 1500-3000

How to fix install the condensate trap: step by step

  1. Insert the 3/4 in PVC elbow through the trap inlet connection ferrule nut.
  2. Slide the trap inlet gasket up onto the 3/4 in PVC elbow.
  3. Confirm the trap float is in place.
  4. Tighten the inlet ferrule nut fully onto the trap.
  5. Slide the 1 in Fernco fitting onto the 3/4 in elbow and tighten the hose clamp with a 5/16 in nut driver or flat screwdriver.
  6. Confirm the bottom trap connection is fully tight.
  7. Slide the trap onto the heat exchanger condensate drain and tighten its hose clamp.
  8. Secure the trap bracket to the boiler base.
  9. Secure the trap to the bracket with the U-bolt.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: SVF Series 1 boiler manual, p. 46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.