Weil-McLain Boiler: Install propane orifice for conversion
Install propane orifice for conversion on a Weil-McLain boiler: Required for all Ultra models except the Ultra-399 (throttle adjustment instead) and the factory propane Ultra-80LP. Use only the orifice size marked for the boiler size.
Applies to: Propane conversion of Ultra boilers (not Ultra-399 and not Ultra-80 natural gas units needing a burner)
How to fix install propane orifice for conversion: step by step
- If the boiler is already installed, turn off electrical supply and close the external manual gas shut-off valve. Let the boiler cool if it was operating.
- Verify the orifice size marking matches the boiler size (see Figure 43).
- For Ultra-105 or Ultra-80LP, install the propane orifice as shown in Figure 44.
- For altitudes above 5,500 ft, use only the special-order high altitude propane orifice kit.
- Affix the propane conversion label to the jacket.
- Start up the boiler and verify operation of the boiler and all system components per the manual.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Ultra Series 4 gas-fired water boiler manual, p. 48. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.