Hydrostatic pressure test procedure on a Weil-McLain boiler: Pressure test the boiler before connecting permanent piping. Use Figure 2 for the connection layout.
Applies to: Ultra Series 4 boilers
How to fix hydrostatic pressure test procedure: step by step
- Remove the supply line tees and 3/4 in elbow from the accessory bag and pipe them to the supply connection. Use pipe dope sparingly.
- Temporarily plug the 3/4 in relief valve tapping in the street elbow with a 3/4 in NPT plug.
- Connect a hose from the fresh water supply to the boiler drain valve. Make sure it can also drain the boiler after the test.
- Install a nipple and shutoff valve on the supply tee to bleed air during fill (not included with boiler).
- Install a shutoff valve on the return connection (not included with boiler).
- Pipe street elbows on top of the shutoff valves and place catch buckets below if you want to avoid water on the boiler.
- Open the shutoff valves, then slowly open the drain valve and fresh water supply to fill. Close the drain when water reaches the shutoff valves.
- Close the shutoff valves, then slowly reopen the drain until the gauge reads 45 to 55 psig.
- Hold for 10 minutes and confirm the gauge pressure stays constant. Check for leaks and repair any found.
- Disconnect the fill hose, drain the boiler through the drain valve, and remove the hose.
- Remove the nipples and valves unless they stay in the system piping.
- Remove the plug from the relief valve street elbow and install the relief valve per page 9.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Weil-McLain Series 4 gas-fired water boiler manual, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.