Weil-McLain Boiler: Heat exchanger coating: cleaning limits
Heat exchanger coating: cleaning limits on a Weil-McLain boiler: The heat exchanger is coated to stop aluminum oxide forming. Mechanical cleaning can shorten the coating life. Heat exchanger inspection is recommended yearly.
Applies to: Ultra Series 4 boilers with coated heat exchangers
How to fix heat exchanger coating: cleaning limits: step by step
- For the first 5 years, vacuum or rinse the heat exchanger with water only. No tool cleaning is needed.
- Clean only when soiling is clearly present, and flush only with water and mild detergent.
- From the cover plate opening, check the collection area and under the vent pipe for debris.
- Cleaning should not be needed until 5 years after the commissioning date.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Ultra Series 4 boiler manual, p. 126. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.