Weil-McLain Boiler: Gas leak check and pressure testing

Updated · by Aurora Star Tech Inc.

Gas leak check and pressure testing on a Weil-McLain boiler: Check the boiler and its gas connection for leaks before operating.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3 all models

How to fix gas leak check and pressure testing: step by step

  1. If a pressure test is above 14 in. w.c., disconnect the boiler from the gas supply and cap the open end of the system gas supply.
  2. Check for leaks with a bubble test only.
  3. Do not check for gas leaks with an open flame.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec series 3 condensing gas boiler boiler manual, p. 64. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.