Weil-McLain Boiler: Electrical entrances and wiring knockouts
Electrical entrances and wiring knockouts on a Weil-McLain boiler: Knockouts are separated by voltage type. Keep line and low voltage wiring in their own areas.
Applies to: Field wiring
How to fix electrical entrances and wiring knockouts: step by step
- Use the front left knockouts for line voltage and external pump voltage only; they lead to the high voltage junction box (item 20).
- Use the bottom right and top right knockouts for low voltage wiring only.
- Seal all wiring entrances.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec Series 3 boiler manual, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.