Weil-McLain Boiler: Domestic water filtration and hardness
Domestic water filtration and hardness on a Weil-McLain boiler: Filtering and softening protect the DHW flow sensor and brazed plate heat exchanger.
Applies to: Combi DHW supply
How to fix domestic water filtration and hardness: step by step
- Install a 25 micron or finer filter on the cold line feeding the combi boiler.
- Use a finer filter or water softener in harsh water conditions.
- Install a water softener if water hardness is above 50 ppm calcium carbonate.
- Install drain and isolation valves on the DHW inlet and outlet so the heat exchanger can be flushed.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec Series 3 boiler manual, p. 49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.