Weil-McLain Boiler: Domestic hot water scald protection and T&P relief valve
Domestic hot water scald protection and T&P relief valve on a Weil-McLain boiler: Hot water can scald. Set the domestic hot water temperature with scald risk in mind and make sure a temperature and pressure relief valve is installed.
Applies to: EG and PEG Series 7 boilers with domestic hot water
How to fix domestic hot water scald protection and t&p relief valve: step by step
- Use a domestic hot water temperature of 130 F or less, which the manual cites as the Consumer Product Safety Commission and some state recommendation.
- If an automatic mixing valve is installed, select and install it per the valve maker's instructions and local standards.
- Use the lowest practical temperature setting for the building's occupants.
- Check the water temperature at a tap right after the first heating cycle and after any adjustment.
- Confirm a temperature and pressure (T&P) relief valve is installed; the manual says this is required.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Weil-McLain EG/PEG Series 7 Boiler Manual, p. 64. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.