Weil-McLain Boiler: Display blank but boiler operates (display communication lost)

Updated · by Aurora Star Tech Inc.

Display blank but boiler operates (display communication lost) on a Weil-McLain boiler: Communication from the control to the display is lost.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ECO Tec Series 3

Common causes of display blank but boiler operates (display communication lost)

  • Loose connection or poor pin engagement at plug J14.
  • Broken wire harness between display, communications board and control.
  • Failed display module.

How to fix display blank but boiler operates (display communication lost): step by step

  1. Check plug J14 and the back of the display board for loose connections and proper pin alignment.
  2. Check continuity on the wire harness from the display to the communications board to the control board.
  3. Cycle power off and on and check operation.
  4. Replace the display module with the correct part from the Parts section.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: ECO Tec Series 3 boiler manual, p. 163. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.