Weil-McLain Boiler: Direct exhaust sidewall termination assembly
Direct exhaust sidewall termination assembly on a Weil-McLain boiler: The termination needs the boiler kit plates plus installer-supplied parts; do not leave exposed vent pipe longer than shown.
Applies to: Ultra direct exhaust sidewall termination
Common causes of direct exhaust sidewall termination assembly
- Exposed vent pipe too long, condensate freezes and blocks the vent
- Outer plate with no stop, so the elbow can be pushed inward
How to fix direct exhaust sidewall termination assembly: step by step
- Gather installer-supplied vent piping, cover plates, galvanized thimble, vent termination elbow and bird screen.
- Trim the supplied metal plates for cover plates only when the hole size matches the vent diameter.
- Insert the piping from the boiler vent connection, then attach the exterior termination piping.
- Install the vent termination using one of the two configurations in Figure 98.
- Seal exterior openings with exterior caulk.
- Do not extend exposed vent pipe outside the building more than the manual shows.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Ultra Series 4 boiler manual, p. 88. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.