Updated · by Aurora Star Tech Inc.

DHW priority turns off space heating on a Weil-McLain boiler: When DHW is priority 1, the U-Control turns off space heating and the boiler circulator during DHW heating. An optional timeout setting can override this. The flow/check valve on the boiler outlet stops gravity circulation during DHW heating.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Systems with indirect DHW tank

How to fix dhw priority turns off space heating: step by step

  1. Set the DHW input to priority 1 when space heating should pause during DHW heating.
  2. Set the optional timeout if space heating must continue during DHW heating.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

More other tips for boiler

Source: Ultra Series 4 boiler manual 550-100-440/1025, p. 52. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.