Updated · by Aurora Star Tech Inc.

Combustion air from the boiler room (inside air) on a Weil-McLain boiler: The SVF can use inside air only when no contaminants are present. Where contaminants are likely, install it as direct vent. The boiler room needs openings sized for all appliances and exhaust fans in the room. The boiler room must never be under negative pressure unless every appliance is direct vent.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Direct exhaust combustion air from boiler room

Common causes of combustion air from the boiler room (inside air)

  • Negative pressure in the boiler room from exhaust fans or mechanical ventilation
  • Louvers or grilles reducing free area
  • Tight construction stopping outside air from reaching the room

How to fix combustion air from the boiler room (inside air): step by step

  1. Confirm no contaminants are present in the boiler room before using inside air.
  2. If contaminants are likely, install the boiler as direct vent.
  3. Size the air openings for all appliances and air movers using the room air, not just the boiler.
  4. Use Figure 26 on page 33 for opening sizes based on the installation conditions.
  5. Reduce the free area of openings for any louver or grille.
  6. In tight construction, provide air openings from outside sized per Figure 26.
  7. Do not let exhaust fans or air movers pull the boiler room under negative pressure.
  8. The damper or louver control can supply 120V to a damper and take a closure switch input to prove the damper is open.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: SVF Series 1 Boiler Manual, p. 32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.