Weil-McLain Boiler: Combi-only components
Combi-only components on a Weil-McLain boiler: These parts are present only on Combi models (DHW side of the boiler).
Applies to: ECO Tec Series 3 Combi models
How to fix combi-only components: step by step
- Brazed plate heat exchanger (item 33) transfers heat from boiler water to domestic water.
- DHW outlet temperature sensor (item 34) controls input based on how close the water is to set point.
- DHW 3-way valve (item 35) and actuator (item 36) route boiler water through the brazed plate or bypass it to the heating system.
- DHW flow sensor (item 37) starts the boiler and lets it modulate when flow of 0.5 GPM or more is detected.
- DHW inlet and outlet pipes (items 39 and 40): 199 uses 3/4 inch NPT; 150 and 110 use 1/2 inch NPT.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: ECO Tec Series 3 boiler manual, p. 8-10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.