Weil-McLain Boiler: Cleaning main burners
Cleaning main burners on a Weil-McLain boiler: Clean the main burners by vacuuming or brushing off dust and lint. Reseat them correctly when reinstalling, or the boiler can fail to operate safely.
Applies to: EG and PEG Series 7 boilers
How to fix cleaning main burners: step by step
- Vacuum or brush the main burners to remove dust and lint.
- When replacing burners, seat the burner tubes in the slots at the back with the openings facing up.
- Check that the gas orifices inject down the center of each burner.
- Improperly seated burners can cause severe injury, death or property damage.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: EG / PEG Series 7 Boiler Manual, p. 72. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.