Updated · by Aurora Star Tech Inc.

Clean temperature/LWCO sensor on a Weil-McLain boiler: Deposits on the probe reduce boiler performance and must be cleaned at annual inspection.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: EG and PEG Series 7 boilers

Common causes of clean temperature/lwco sensor

  • Mineral or contaminant buildup on the probe surface

How to fix clean temperature/lwco sensor: step by step

  1. Disconnect power and unplug the harness from the sensor.
  2. Drain the boiler water to a level below the sensor.
  3. Remove the sensor from the boiler.
  4. Wipe any buildup from the probe and insulator surfaces.
  5. Reinstall the sensor into the boiler.
  6. Refill the boiler to the correct waterline.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Weil-McLain EG/PEG Series 7 Boiler Manual, p. 69. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.