Updated · by Aurora Star Tech Inc.

Circulator zoning, primary/secondary piping on a Weil-McLain boiler: Each zone has its own circulator. The boiler loop is a secondary circuit off the primary loop.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: SVF 1500-3000 Series 1

How to fix circulator zoning, primary/secondary piping: step by step

  1. Install a separate circulator for each zone, sized for the flow and head needed.
  2. Install a flow/check valve on the boiler outlet piping.
  3. The boiler circulator cannot be used as a zone pump.
  4. Keep boiler loop piping at least the minimum size in Figure 11, page 16.
  5. For more than 3 zones, use a Weil-McLain WMCR zone circulator controller.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: SVF Series 1 boiler manual, p. 21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.