Weil-McLain Boiler: Check burner flame (annual startup)
Check burner flame (annual startup) on a Weil-McLain boiler: Inspect the flame through the observation window. Clean or replace the burner if the flame is poor at high or low fire.
Applies to: Ultra 80, 105, 155, 230, 299, 399
Common causes of check burner flame (annual startup)
- Dirty or fouled burner
- Damaged burner gasket
- Loose burner retainer tabs
How to fix check burner flame (annual startup): step by step
- Look at the flame through the observation window (procedure on page 40) at high fire and low fire.
- If the flame is unsatisfactory, shut off the boiler and let it cool.
- Remove the burner and clean it with a vacuum or compressed air. Do not use compressed air indoors.
- Remove the heat exchanger cover plate (page 125) to reach the burner.
- When refitting, check the gasket is good and correctly placed.
- After tightening the three retainer screws, bend up the retainer tabs.
- Reattach the cover plate per Figure 126 (page 126) or Figure 128 (page 127), then retest the boiler.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Ultra Series 4 gas-fired water boiler manual, p. 112. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.