Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Boiler: Access and clean heat exchanger, Ultra-80 and Ultra-105

Updated · by Aurora Star Tech Inc.

Access and clean heat exchanger, Ultra-80 and Ultra-105 on a Weil-McLain boiler: Removes the blower, venturi, gas valve and cover plate as one assembly for pin-side cleaning.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Ultra-80 and Ultra-105 only

How to fix access and clean heat exchanger, ultra-80 and ultra-105: step by step

  1. Close the external manual gas valve.
  2. Disconnect the flexible gas line at its flare fitting.
  3. Remove the air silencer from the air adapter on the blower inlet.
  4. Disconnect: gas valve plug, blower power plug, blower control connector, ignition cable and ground wire.
  5. Remove the nuts holding the heat exchanger cover plate and release the plate.
  6. Pull the blower/venturi/gas valve/cover plate assembly out of the boiler.
  7. Vacuum the heating surfaces. Do not use solvent.
  8. If needed, wash with clean warm water. For further cleaning use the heat exchanger cleaning tool or 20-gauge or lighter sheet metal, 3/4 in wide by about 18 in long.
  9. Inspect the cover plate insulation and replace it if damaged. Read the ceramic fiber warning on page 109 first.
  10. Reinstall the assembly. Tighten cover nuts in two or three passes to the sequence in Figure 126; final torque must not exceed 50 in-lb (±10 in-lb).
  11. Make sure the O-ring in the gas valve inlet adapter block is in good condition and installed if the block was removed. Without it a gas leak can occur.
  12. Reconnect the wiring, flexible gas line and air silencer.
  13. Perform a soap suds leak test on all interior gas piping after starting the boiler.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Ultra Series 4 boiler manual, p. 126. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977