Viessmann Boiler: System layout 7: direct circuit plus system separation
System layout 7: direct circuit plus system separation on a Viessmann boiler: One direct-connected radiator circuit plus an underfloor circuit with system separation through a plate heat exchanger. Boiler pump supplies the radiator circuit and the plate heat exchanger.
Applies to: Direct radiator circuit with system separation
How to fix system layout 7: direct circuit plus system separation: step by step
- Install the plate heat exchanger for system separation.
- Size the plate heat exchanger secondary pressure drop to be less than or equal to the 3-way mixing valve pressure drop.
- Install the mixing valve accessory kit and sensor on the underfloor circuit.
- Pipe the DHW circulating pump into the boiler.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HA installation manual, p. 39. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.