Viessmann Boiler: System layout 3: DHW storage tank with closely spaced tees

Updated · by Aurora Star Tech Inc.

System layout 3: DHW storage tank with closely spaced tees on a Viessmann boiler: Layout with DHW storage tank and one heating circuit using closely spaced tees instead of a low-loss header. Viessmann prefers a low-loss header.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 100-W WB1B 26 and 35

How to fix system layout 3: dhw storage tank with closely spaced tees: step by step

  1. Install closely spaced tees at 4 times the pipe diameter or 12 in (305 mm) apart.
  2. Install the primary pump so it pumps into the boiler.
  3. Install the external boiler/DHW controller and DHW tank aquastat or sensor.
  4. Install the air vent, PRV, TPV and expansion tank as shown.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 100-W, WB1B CombiPlus Installation & Service Instructions, p. 40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.