Viessmann Boiler: Route low-voltage and 120 V connecting cables
Route low-voltage and 120 V connecting cables on a Viessmann boiler: Keep cables clear of hot components, since they will be damaged if touching them. Cables must stay within their rated temperature.
Applies to: Vitodens 200-W B2HB wiring
How to fix route low-voltage and 120 v connecting cables: step by step
- Route low-voltage cables and 120 V cables to their connection areas.
- For larger cable sizes (up to 9/16 in.), remove the existing cable grommet and secure the cable with the grommet in the lower (orange) casing section.
- Secure all cables to the control base using the existing strain reliefs.
- Keep the power cable grommet in place for the 120 V connections.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB installation manual, p. 24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.