Viessmann Boiler: Route and secure field wiring
Route and secure field wiring on a Viessmann boiler: Keep connecting cables away from hot components and do not exceed their maximum temperature rating. Use the cable grommet for power cable entry and secure cables to the control base strain reliefs. Discharge static before touching electronics.
Applies to: Vitodens 200-W B2HA 80-100, 285-352
How to fix route and secure field wiring: step by step
- Touch a grounded object such as a heating or water pipe before working on electronic modules.
- Remove the existing cable grommet when using larger cables.
- Plug the grommet into the lower casing section (black) and secure the cable.
- Route all connecting cables to their areas and secure them to the control base strain reliefs.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HA installation instructions, p. 24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.