Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Removing the hydraulic unit (B1HE/KE 150/199)

Updated · by Aurora Star Tech Inc.

Removing the hydraulic unit (B1HE/KE 150/199) on a Viessmann boiler: Removal sequence for the hydraulic unit on the 150 and 199 models.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: B1HE and B1KE 150/199

How to fix removing the hydraulic unit (b1he/ke 150/199): step by step

  1. Remove the control unit.
  2. Loosen the union nut on the gas pipe, holding it with an open ended wrench.
  3. Remove the burner.
  4. Pull off the clip and remove the flow switch.
  5. Pull off the clips and remove the supply pipe toward the front. Use new cable ties when refitting.
  6. Remove the screws on the hydraulic plate at the bottom of the boiler.
  7. Undo the union nut of the boiler pump.
  8. Remove the hydraulic unit.
  9. Refit in reverse order.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Viessmann Vitodens 100-W B1HE/B1KE installation/service manual, p. 88. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977