Viessmann Boiler: Remove front panel and burner

Updated · by Aurora Star Tech Inc.

Remove front panel and burner on a Viessmann boiler: Isolate power and gas before service. Do not lay the burner on its cylindrical tube.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 100-W, WB1B

How to fix remove front panel and burner: step by step

  1. Isolate and lock out the main power supply and shut off the main gas supply.
  2. Loosen the bottom screws of the front panel without removing them fully, then remove the panel.
  3. Switch the burner off at the main service switch and shut off the gas supply.
  4. Unplug the cables from the fan motor, gas valve and electrode block.
  5. Pull the Venturi extension from the fan.
  6. Release the gas supply pipe fitting. A gasket sits between the gas valve and this connection.
  7. Remove the four Torx T-30 screws and take the burner out.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Viessmann Vitodens 100-W, WB1B installation and service instructions, p. 67-68. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.