Viessmann Boiler: Remove front enclosure panel and fill condensate trap
Remove front enclosure panel and fill condensate trap on a Viessmann boiler: Required before some service steps. Gas must be shut off first. The condensate trap is filled with water before the first start.
Applies to: Vitodens 200-W B2HB boilers
How to fix remove front enclosure panel and fill condensate trap: step by step
- Close the main gas supply valve.
- Remove the external accessories connection box cover.
- Loosen the bottom screws without removing them completely.
- Slide out and remove the front enclosure panel.
- Remove the retaining clip from the condensate trap and set it aside.
- Disconnect the condensate trap and fill it with water.
- Reinstall the condensate trap and secure it with the retaining clip.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199
Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 Service Instructions, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.