Viessmann Boiler: Prepare the power pump module for CombiPLUS
Prepare the power pump module for CombiPLUS on a Viessmann boiler: Remove the parts that block CombiPLUS operation and the room thermostat jumper, using static-safe handling.
Applies to: Vitodens 100-W WB1B power pump module
How to fix prepare the power pump module for combiplus: step by step
- Discard the static-sensitive parts carefully, following electrostatic discharge procedures.
- Remove the jumper pin from terminal X8 (CombiPLUS) and discard it.
- If a room thermostat is connected, remove the jumper cable from terminal block X4 (terminals 3 and 4) and discard it.
- Remove the second and fourth hole plugs from the base of the power pump module and discard them.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 100-W WB1B installation and service instructions, p. 31. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.