Viessmann Boiler: Mount the boiler on wall bracket or free-standing frame
Mount the boiler on wall bracket or free-standing frame on a Viessmann boiler: Install the wall bracket or stand first, then hang the boiler and level it. The B2HB has no mounting template, so the wall positions for the frame, bracket and vents must be calculated in the field. Boiler must be level both ways so condensate drains.
Applies to: Vitodens 200-W B2HB 19 to 35, 68 to 125
How to fix mount the boiler on wall bracket or free-standing frame: step by step
- Fasten the boiler stand or frame securely to the floor, using concrete anchors. Wall-fixing for the frame may also be needed.
- Attach the wall mounting bracket to the boiler mounting frame with the supplied hardware. Check that the bracket is level.
- Remove the external accessories connection box cover and loosen (do not remove) the bottom boiler screws.
- Remove the front enclosure panel by lifting it up and pulling it away from the boiler.
- Hang the boiler on the mounting bracket, make sure it is secure, and fit the holding bracket to the frame above the boiler.
- Adjust the levelling screws until the boiler is level vertically and horizontally.
- Connect the boiler to the installation fittings.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB installation manual, p. 16-17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.