Viessmann Boiler: Lighting and starting the appliance
Lighting and starting the appliance on a Viessmann boiler: Start-up sequence from the lighting label. The appliance has an ignition device and has no pilot, so do not light it by hand.
Applies to: Vitodens 200-W B2HB 19 to 35, 68 to 125
How to fix lighting and starting the appliance: step by step
- Set the thermostat or other control to the lowest setting.
- Turn off all electric power to the appliance.
- Close the main gas shut-off valve.
- Wait five minutes to clear any gas, then smell for gas including near the floor.
- If gas is smelled, stop and follow the gas smell response steps.
- Open the main gas shut-off valve.
- Turn on all electric power to the appliance.
- Set the thermostat or control to the desired setting.
- If the appliance will not operate, turn off the gas as described and call a service technician or the gas supplier.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB installation manual, p. 61. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.