Viessmann Boiler: Lighting and shutting off gas to the appliance (label procedure)
Lighting and shutting off gas to the appliance (label procedure) on a Viessmann boiler: Label procedure for the gas supply. The appliance has no pilot; it uses an electronic ignition. Never light the burner by hand and never use tools on the gas control knob.
Applies to: Vitodens 200-W B2HB 19 to 125
How to fix lighting and shutting off gas to the appliance (label procedure): step by step
- Before operating, smell all around the appliance, including near the floor, for gas.
- If gas is smelled, do not light anything, do not touch electrical switches, and leave the area to call the gas supplier from outside.
- Set the thermostat or control to its lowest setting.
- Turn off all electric power to the appliance.
- Close the main manual gas shut-off valve.
- Wait five minutes to clear any gas, then smell again near the floor.
- Open the main manual gas shut-off valve.
- Turn on electric power to the appliance.
- Set the thermostat or control to the desired setting.
- If the appliance will not run, shut off gas as below and call a service technician or the gas supplier.
- To shut off gas: set the control to lowest, turn off electric power if service is needed, then close the main manual gas shut-off valve.
- Do not use the appliance if any part has been under water; have a qualified technician inspect it and replace the affected control and gas control parts.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199
Source: Vitodens 200-W B2HB 19 to 125 service instructions, p. 103. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.