Viessmann Boiler: Installing the burner

Updated · by Aurora Star Tech Inc.

Installing the burner on a Viessmann boiler: Reverse of burner removal. Torque values are critical. Check all gas fittings for leaks before startup.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: B1HE/KE 85/120 and 150/199

How to fix installing the burner: step by step

  1. Move the programming unit if needed.
  2. Insert the burner and tighten the screws diagonally to 35 lb.in (4 Nm).
  3. Fit the gas supply pipe with a new gasket and tighten to 22 lb.ft (30 Nm).
  4. Check the gas connections and shut-off valve for leaks.
  5. Reconnect the fan motor (2 plugs), ionization electrode, ignition unit and ground.
  6. Keep the gas pipe from twisting and make sure it does not touch any other component. Use the two-wrench method, not pliers.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 56. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.