Viessmann Boiler: Gas supply sizing and pressure drop

Updated · by Aurora Star Tech Inc.

Gas supply sizing and pressure drop on a Viessmann boiler: Gas piping must be sized from pipe length, fittings, gas type and the total input of all gas appliances in the building. There must be no noticeable pressure drop when any appliance (or combination) lights or runs. Maximum gas supply pressure is 14 in. w.c. Design the layout so piping does not block serviceable components.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HA 45, 60

How to fix gas supply sizing and pressure drop: step by step

  1. Size the gas line using CAN/CSA B149.1 and .2, or NFPA 54 / ANSI Z223.1, plus local codes.
  2. Confirm the line can carry the total input of all appliances in the building.
  3. Check that no pressure drop is seen when appliances light or run.
  4. Do not exceed 14 in. w.c. gas supply pressure.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More commissioning tips for boiler

Source: Vitodens 200-W B2HA 45, 60 Installation Instructions, p. 19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.